1. The connection between the servomotor shaft and the lead screw is loose, which leads to synchronization with engine and dimensional errors.
During the inspection, you just have to mark the coupling between the servomotor and the lead screw, and move the holder (or the tool holder) from front to faster due to The inertia of the Ouchette (or the turret), the turret, the turret, the turret, the turret, the turret, the turret, the coupling will be done. These defects generally occur when the size of the treatment only changes in one direction, and the coupling screws are simply tightened uniformly to eliminate.
Click to receive the CNC 10G programming tutorial for free
2.
These faults generally occur when the size of the part changes in a few wires, and the defect is eliminated by simply improving lubrication.
3. The mobile resistance of the Machine-Outil Workbench (or tool holder) is too large, which is generally caused by an excessive tight adjustment of the insert and poor lubrication of the surface of the Rail of the Machine Guide-Outil .
This defect phenomenon is generally manifested in irregular changes in the size of the room in a few wires. During the inspection, this can be done by observing the magnitude and changes in the quantity of DGN800-804 position deviation. These failures simply require the readjustment of the insert and improve rail lubrication.
4. The rolling bearing is worn or poorly adjusted, resulting in excessive resistance of movement.
This defect phenomenon is also generally manifested as irregular size changes in a few wires. During the inspection, it can be carried out by the quantity of DGN800-804 position deviation, the method is the same as above. These faults can be eliminated by simply replacing the worn bearings and by carefully adjusting them.