The thread striker accelerates excessive wear or wear
1. Reason: the cutting speed and the quantity of power are not selected correctly.
Solution: Make sure you select the cutting speed and correct power speed in the machining settings table.
2. Reason: the tool is under too much pressure.
Solution: Reduce the flow by tooth; shorten the time change time interval; Check the excessive wear of the tool – the thread at the start carries the fastest.
3. Reason: The selected coating is incorrect, resulting in a dispersed tumor.
Solution: study the applicability of other coatings; Increase the flow rate and flow of the coolant.
4. Reason: The speed of the spindle is too high.
Solution: Reduce the speed of the spindle.
Point
1. Reason: the cutting speed and the quantity of power are not selected correctly.
Solution: Determine the cutting speed and the correct amount of power supply selected in the table of machining parameters.
2. Cause: The thread striker moves or slips on its tightening device.
Solution: Use the hydraulic chuck.
3. Reason: the machining tool is not rigid enough.
Solution: Make sure the part is tight reliably;
4. Reason: Insufficient cooling liquid pressure or flow.
Solution: Increase the flow rate and flow of the coolant.
The steps appear on the threaded tooth
1. Reason: the power rate is too high.
Solution: Reduce food by tooth.
2. Reason: The treatment and programming of the slope grinding adopt the axial movement.
Solution: Make sure that the thread striker is ground for the large diameter of the wire
3. Reason: the milling striker is excessively worn.
Solution: shorten the time change time interval.
4. Reason: the tool processing part and the tightening part are too far away.
Solution: shorten the amount of overhang of the tool on the tightening device as much as possible.
There are differences in the detection results between parts
1. Reason: The tool processing part and the tightening part are too far away.
Solution: shorten the amount of overhang of the tool on the tightening device as much as possible.
2. Reason: The selected coating is incorrect, resulting in a dispersed tumor.
Solution: study the applicability of other coatings; Increase the flow rate and flow of the coolant.
3. Reason: the milling striker is excessively worn.
Solution: shorten the time change time interval.
4. Reason: the room is moved to the luminaire.
Solution: Make sure the part is tight reliably;
Daguang focuses on providing solutions such as precision CNC machining services (3-axis, 4-axis, 5-axis machining), CNC milling, 3D printing and rapid prototyping services.